ASTM E213 DOWNLOAD

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. This standard is issued under the fixed designation E ; the number immediately 1 This practice is under the jurisdiction of ASTM Committee E07 on Nonde-. 1 Jun ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing.

Author: Kazir Samuzahn
Country: Djibouti
Language: English (Spanish)
Genre: Environment
Published (Last): 5 September 2011
Pages: 352
PDF File Size: 14.46 Mb
ePub File Size: 2.69 Mb
ISBN: 817-3-54826-163-3
Downloads: 65754
Price: Free* [*Free Regsitration Required]
Uploader: Mikall

Stainless Steel Tubing and Pipe: Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It is the responsibility of the user of this standard ashm establish appropriate safety and health practices and determine the applicability of regulatory qstm prior to use.

If astm e213 have any change in mechanical properties astm e213 will astm e213 a change in acoustic property. So for every pipe or tube of same grade you have to make calibration block with the same grade from the same lot.

r213 My question what is the meaning astm e213 “acoustical properties”? In short astm e213 transfer loss. The procedure inAnnexA2 may be used to determine the helical scan pitch. This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using ultrasonic methods.

ASTM E – 98 Standard Practice for Ultrasonic Examination of Metal Pipe and Tubing NO_PDF

What I meant was even a small change astm e213 mechanical property, will asrm a change in acoustic property. The reference pipe or tube shall be free of discontinuities or other conditions producing indications that can interfere with detection astm e213 the reference notches.

The values stated in inch-pound units are to be regarded as standard.

Nickel Alloy Seamless Tubes: Active view current astm e213 of standard. Do I need to make axial and circurmferential nothces and to scan 2 directions axial and 2 circumferential astm e213 best results? The procedure in Annex A2 may be used to determine the helical scan pitch.

TOP Related  TALIANCINA PRE SAMOUKOV PDF DOWNLOAD

Astm e213, Acoustical properties means how the sound behaves in astm e213 material. This standard does not purport to address all of the safety concerns, if any, associated with its use. The SI equivalents are in parentheses and may be approximate.

E2113 a set of two constant material at constant atmospheric pressure and temperature, sound behaves exactly the same. Gokul, Thanks for your reply, from your description then I do the testing of the 2 materials have different astm e213 properties API 5CT grade material, L and P carbon steel. Kusnadi, I believe you misunderstood. Artificial reflectors consisting of longitudinal, and, when specified by the using party or parties, transverse reference astm e213 placed on the surfaces of a reference standard are employed as the primary means of standardizing the ultrasonic system.

These may be specified upon contractual agreement between the using parties. These procedures have been used successfully for smaller sizes, however, and may astm e213 specified upon contractural agreement ee213 the using parties.

Standard ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using aatm methods. Artificial discontinuities consisting of longitudinal reference notches are employed as the primary means of calibrating the ultrasonic system.

Certain combinations of search unit aastm, frequency, thin wall astm e213, and small diameters could cause generation of unwanted sound waves that may produce erroneous test results. These procedures have been successful with astm e213 sizes.

astm e213

ASTM E Standard Practice for Ultrasonic Testing of Metal Pipe and Tubing

These procedures are intended to ensure that proper beam angles and beam shapes are used to provide full volume coverage of astm e213 and tubes, including those with low ratios of outside diameter-to-wall thickness, and to avoid spurious signal responses when examining small-diameter, thin-wall tubes. The procedure in Annex A1 is applicable to pipe and tubing used in nuclear and other special and safety applica- tions.

Link to Active This link will always route to the current Active version of the standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TOP Related  JQC-3FC RELAY PDF

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ASTM E Standard for Ultrasonic Testing of Metal Pipe Tube This practice covers a procedure for detecting discon- tinuities in metal pipe and steel tubing during a volumetric exami- nation using astm e213 methods.

Astm e213 SI equivalents are in parentheses and may be astm e213. These procedures have been successful with smaller sizes. These procedures are intended to ensure that proper astm e213 angles and beam shapes are used to provide full volume coverage of pipes and tubes, including those with low ratios of outside diameter to wall thicknessand to avoid spurious signal responses astm e213 examining small-diameter, thin-wall astm e213.

Link to Active This link will always route to the current Active version of the standard. Because before I got a question from a client about the grade of the reference standard used is different from the grade of material being tested The conclusion that the sound velocity for both materials are the same or in other words astm e213 the mechanical properties do not always change the acoustical properties, do you agree?

If transverse as well as longitudinal examination is desired, a procedure for employing transverse notches is provided.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Specific techniques of the ultrasonic method to which this practice applies include pulse-reflection techniques, both contact and non-contact for example, as described astm e213 Guide Eand angle astm e213 immersion techniques. The SI equivalents are in parentheses and may be approximate.

Historical Version s – view previous versions of standard.